Start-Up Procedures
1) Remove the Oil Filler Plug, and ensure that there
is Oil in the Crankcase. Refer to the "Lubrication"
section in the pertinent Compressor Unit manual
for the proper type and level of Oil.
2) Replace the Oil Filler Plug, and tighten as
required. Refer to Compressor Unit manual.
3) Do a visual inspection of the Unit, and e n s u r e
that all Bolt heads are sufficiently tightened. This
must be done, as some fasteners may become
loose in transit.
4) Turn the Compressor 'On' momentarily by
positioning the Fused Disconnect in the 'On'
position. Ensure that the Flywheel is turning in
the correct direction. Pit Boss Units rotate only
one way. For Heavy Duty Units, see "Pump
Rotation" (page 10) in Unit manual.
6) After having run the Compressor Unit for 30
minutes, close the Ball Valve, and allow the unit
to reach maximum operating pressure. Ensure
that the Compressor shuts down at the pre-set
maximum pressure, and the head pressure is
released through either the front of the Pump (the
CPR) or at the Pressure Switch.
7) Check the Compressor and Piping Systems for
air leaks, and correct as required.
8) Stop the Compressor, and check the Oil level in
the Crankcase. Add Oil as required.
5) Open the Compressor's Ball Valve, and start the
Unit. Ensure that the air is escaping to
atmosphere. Allow the Unit to operate in this
fashion for approximately 30 minutes. This
lubricates the Pistons, Bearings, and all internal
surfaces.
Do not place any materials on or against the
Belt Guard, or the Compressor Unit as a whole.
Placing materials there will limit the cooling of
the Compressor, and could lead to premature
failure.
1. Please note that, under normal operating conditions, the Compressor Unit
will operate intermittently. The Unit starts/stops without warning.
2. Shut off all power to the Air Compressor Unit before attempting any repair
or maintenance.
On Compressors with 3 phase power, adjust
the wiring at the Motor terminals if the rotation
is incorrect. Refer to the wiring diagram on or in
the Motor terminal box.
Do not attempt to operate the Unit without first
checking whether there is Oil in the Pump. Add
Oil as required. Serious damage may result
from use, however limited, without Oil.
The following is a guideline which the Customer must follow in the correct initial start-up of their new Compressor
Unit. Please pay close attention to the various Notes, Cautions, and Warnings.
NOTE
NOTE
During the first few days of operation, check the Unit periodically to ensure it is
running smoothly and the controls are operating properly. Should you notice any
areas of concern, contact your Devair Distributor or Authorized Service Centre.
NOTE
- 16 -
On-Site Electrics
What is involved in the ‘initial start-up’ of the Unit ?
Air Compressors
Information Bulletin IFB-01
March ‘07